Air showers are specialized enclosed antechambers which are incorporated as entryways of cleanrooms and other controlled environments to reduce particle contamination. Air showers utilize high-pressure, HEPA- or ULPA-filtered air to remove dust, fibrous lint and other contaminants from personnel or object surfaces. The forceful "cleansing" of surfaces prior to entering clean environments reduces the number of airborne particulates introduced.
When properly incorporated into cleanroom design, air showers provide an ISO-classified transition vestibule to ensure the cleanliness of the classified cleanroom . Air showers are typically placed between a gowning area and cleanroom; after workers don appropriate garb and personal protective equipment, they enter the shower so that the pressurized air nozzles remove any residual particles from coveralls. Once the program cycle is complete, users exit out through a second door, into the cleanroom. Air showers (or air tunnels) may also be placed between cleanrooms of different ISO ratings.
Video Air shower (room)
Design and functionality
Air showers are generally constructed from cleanroom-compatible steel or plastic materials and feature electronically-powered blowers, filters and high-pressure jet nozzles, the latter being incorporated into the walls and ceiling of the chamber. Air, at velocities of 3,000 to 7,000 feet-per-minute (FPM), continuously streams from the jet nozzles for 30-45 seconds, effectively removing loose particulate matter. Personnel inside the enclosure will lift their arms and turn their bodies for uniform exposure to the air streams, a procedure usually specified in protocol. Air currents from the jets create shearing and flapping forces, which lift and remove contaminants from both flat surfaces and the creases of garments. HEPA filtration within the air shower is capable of removing 99.97% of particles greater than 0.3µm diameter.
Air is channeled within the air shower using a closed-loop system, where it is continuously re-circulated. Air is forced through a motorized filter/blower module into a large plenum, then into the shower through jet nozzles. Particle-laden, contaminated air is routed out of the shower compartment through floor vents and returned to the filtration unit. This process ensures that only decontaminated air is used to remove particulates from personnel and other equipment, such as supply carts.
Often, air showers are equipped with air ionizers to reduce static electricity, as large volumes of high-velocity air create electric charges. Since laboratory equipment, electronic measuring instruments and many hi-tech manufactured goods can often be damaged by electrostatic discharge, ionizers are essential in rendering material surfaces electrically neutral prior to entering the cleanroom.
Maps Air shower (room)
Safety
Interlocking mechanisms are a common air shower feature to prevent both exits from being opened simultaneously, which would allow outside air to enter a tightly controlled environment. This requires occupants to stay inside until the decontamination cycle has completed. For this reason, safety features such as emergency stops are required by most safety administrations. Alternatively, the air shower may consist of a long tunnel not equipped with doors; personnel slowly walk through to reach the controlled area. Air handling equipment creates an isolated atmosphere using pressure differentials to create fluid boundaries between the inner and outer environments.
External links
- Cleanroom entry and exit procedures
- Air showers used at NASA
References
Source of the article : Wikipedia